Fire Alarm Certificate in London, Hertfordshire, Bedfordshire and Buckinghamshire

A fire alarm certificate is your proof that the alarms in your building will actually go off when it matters. Smoke spreads fast, so an early warning gives people the minutes they need to get out. A fire alarm certificate shows that a competent engineer has tested every detector, sounder and panel, and that the system meets the right British Standard.

We test, service and certify fire alarms for landlords, HMOs, blocks of flats, offices, shops and other businesses. Most of our work is in London, Hertfordshire, Bedfordshire and Buckinghamshire, and we also travel nationwide for larger jobs and portfolios. Prices start from £90 plus VAT, and we fix every quote before we visit. So if you need a fire alarm certificate for an HMO licence, a letting agent, an insurer or your fire risk assessment, call us on 01442 939006.

What is a fire alarm certificate?

A fire alarm certificate is a signed document from a competent person. First, it records that they have inspected and tested the system, and that it works as it should. It also lists any faults and what needs doing to fix them.

In practice, people use the term for a few different documents:

  • Inspection and servicing certificate: issued after a routine service of an existing system. This is the one most landlords and businesses need.
  • Commissioning and installation certificates: issued when an engineer fits a new system or makes a major change.
  • Smoke alarm certificate: a simpler record for homes and small HMOs with mains-wired, interlinked smoke and heat alarms.

Keep your certificate with your fire risk assessment and fire alarm logbook. In fact, these are often the first documents a fire officer, licensing officer or insurer asks to see.

Is a fire alarm certificate a legal requirement?

The law does not always use the word “certificate”. However, it does require you to keep alarms working, and a certificate is the clearest way to prove you have done that.

  • Businesses and communal areas: under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must keep fire safety systems in efficient working order. This also covers offices, shops and the common parts of flats and HMOs.
  • Private landlords in England: the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 require a smoke alarm on every storey used as living space. They also require a carbon monoxide alarm in any room with a fixed combustion appliance, such as a boiler. The government’s guidance for landlords explains these rules.
  • HMO landlords: in addition, councils usually ask for a valid certificate with every licence application and renewal.

In short, a certificate protects the people in your building. It also protects you if there is a fire, a complaint or an insurance claim.

The British Standards: BS 5839-1 and BS 5839-6

In general, two parts of the British Standard cover most buildings. First, BS 5839-1 covers non-domestic premises, such as offices, shops, care homes and the common parts of some blocks. Then BS 5839-6 covers homes, including flats, houses and most HMOs.

Importantly, BS 5839-1 had a major update recently. BS 5839-1:2025 came into effect on 30 April 2025 and replaced the 2017 edition. Among other things, it adds new guidance on extending and modifying systems. Even so, many websites still quote the old version. Our engineers work to the current standard, so your certificate is up to date.

Grade A and Grade D systems explained

The “grade” describes the type of system. It matters because it decides how often you need servicing.

  • Grade D: mains-powered smoke and heat alarms with a backup battery, linked together so they all sound at once. For example, most houses, flats and smaller HMOs have this type.
  • Grade A: a full system with a control panel, detectors, manual call points and sounders. By contrast, larger HMOs, blocks of flats and commercial buildings usually have this type.

Not sure which you have? If there is a control panel on the wall, it is almost certainly Grade A. Otherwise, it is probably Grade D.

How often should a fire alarm be serviced?

As a rule, the answer depends on the grade:

  • Grade A panel systems: a competent engineer should service them at least every six months. In addition, someone on site should test a call point every week.
  • Grade D alarms: test them regularly with the test button, and arrange a professional check at least once a year.

Similarly, local councils follow the same pattern. For example, Stevenage Borough Council asks HMO landlords with Grade A systems for a certificate dated within the last six months. For Grade D systems, it asks for a certificate at licence time and yearly evidence of checks. The joint Hertfordshire HMO fire safety guidance sets out similar standards across the county.

What our inspection includes

On the day, our engineer first works through the whole system. A typical service covers:

  • testing every smoke detector, heat detector and sounder
  • checking the control panel, fault lights and standby batteries
  • testing manual call points
  • checking that people can hear the alarms in every room
  • looking for damaged, painted-over or blocked detectors
  • checking interlinking between alarms
  • reviewing your logbook and weekly test records

Where possible, we fix small faults on the spot, such as a flat backup battery. For bigger repairs, we give you a fixed quote first.

Your certificate and report

After the visit, you receive:

  • a fire alarm inspection and servicing certificate to the correct part of BS 5839
  • a list of every device tested, with its location and result
  • a clear list of faults, in priority order
  • an updated logbook entry
  • a recommended date for your next service

We write everything in plain English. As a result, you can forward it straight to your council, letting agent, insurer or leaseholders.

Fire Alarm Certificate Cost

Generally, the cost of a fire alarm certificate depends on the grade of system, the number of devices and the location. Here are our typical prices:

Property or systemPrice (plus VAT)
Flat or small house, Grade D, up to 4 alarms£90 to £120
Larger house or small HMO, Grade D, up to 8 alarms£120 to £160
Extra Grade D alarms£15 to £20 each
Grade A panel system, up to 20 devices£150 to £220 per service
Grade A panel system, 20+ devices or commercialFixed quote on request

Prices include the inspection, the certificate and the logbook update. However, replacement alarms, batteries and parts cost extra, and we always ask first. Six-monthly service contracts for Grade A systems also come with a discount. Properties outside London, Hertfordshire, Bedfordshire and Buckinghamshire may include a travel charge, which we show clearly in your quote.

Need other checks too? We can combine your visit with an emergency lighting certificate, PAT testing or a fire door inspection. That way, you save time and a second call-out charge.

Certificates for landlords and HMOs

Of course, landlords make up a big part of our work. Before a new tenancy, we can test the alarms, check they meet the 2022 rules and give you a certificate for your agent. In addition, we can collect keys and work around tenants.

However, HMOs need extra care, because the right system depends on the size and layout of the property. Your fire risk assessment and the council’s licence conditions set the grade and coverage. For licence applications, see our HMO fire risk assessments. For blocks and converted houses, our fire risk assessments for flats also cover the communal alarm system.

Areas we cover

We work across London and the Home Counties every week. As a result, we can usually book you in within a few days:

  • London: all 32 London boroughs and the City of London, including Harrow, Barnet, Brent, Ealing, Hillingdon, Enfield, Camden, Westminster, Islington, Hackney and Croydon
  • Hertfordshire: Watford, Hemel Hempstead, St Albans, Berkhamsted, Tring, Harpenden, Hatfield, Welwyn Garden City, Stevenage, Hitchin, Hertford and Borehamwood
  • Bedfordshire: Luton, Bedford, Dunstable, Leighton Buzzard and Biggleswade
  • Buckinghamshire: Aylesbury, High Wycombe, Milton Keynes, Amersham, Chesham, Beaconsfield and Marlow

Searching for a fire alarm certificate near me? If your town is not listed, please call us anyway. We also cover the rest of England, Wales and Scotland for landlords, agents and national businesses.

Why choose us

  • Fire safety experience since 2010.
  • Servicing by a competent engineer, working to BS 5839-1:2025 and BS 5839-6.
  • Clear prices from £90 plus VAT, fixed before the visit.
  • One provider for fire alarms, fire risk assessments, emergency lighting, fire doors and PAT testing.
  • One point of contact and the same certificate format for multi-site clients.
  • £10m professional indemnity and public liability insurance.

Frequently asked questions

How much does a fire alarm certificate cost?

In short, a fire alarm certificate starts from £90 plus VAT for a flat or small house with up to four alarms. Grade A panel systems start from £150 plus VAT per service. We fix every quote before we visit.

How long is a fire alarm certificate valid?

There is no single expiry date. Grade A systems need a service every six months, so the fire alarm certificate covers six months. For Grade D alarms, most councils expect yearly checks.

Do landlords need a fire alarm certificate?

Landlords must have working smoke alarms and, where needed, carbon monoxide alarms. Therefore, a fire alarm certificate is the best evidence that they work. HMO landlords usually need one for the licence.

Who can issue the certificate?

Only a competent person with the right training and test equipment should issue it. For Grade A systems, this is usually a specialist fire alarm engineer.

What happens if an alarm fails?

First, we record the fault and tell you straight away. Often, we can replace a faulty alarm or battery on the same visit. Otherwise, we give you a fixed quote for the repair.

Can I test the alarms myself?

Yes, and you should. Press the test button on Grade D alarms regularly, and test a call point weekly on Grade A systems. However, a competent engineer should carry out the periodic service and issue the certificate.